FAULT ISOLATION MANUAL
Find the fault.
Then fix it.
Aircraft mechanics don't guess: they open the Fault Isolation Manual and follow numbered blocks until the fault has nowhere left to hide. These sheets bring that discipline to reef chemistry: confirm the reading, eliminate the confounds, verify the equipment, and only then act. No account, no data collected: the sheet runs entirely in your browser.
YES / NO logic · one block at a time until a single cause remains.
-
ALK-001Observed condition: alkalinity decreasing
Alkalinity falls between doses faster than expected, confirmed by trend testing in an intervention-free window. 33-step fault tree: test confidence, trend confounds, supply and delivery verification, consumption vs. precipitation.
OPEN SHEET → -
NO3-001Observed condition: nitrate high
Nitrate reads above the applicable upper boundary for your tank type, confirmed by a second method. 26-step fault tree: reading confirmation, carbon-dosing and phosphate gates, tank-specific critical classification, preflighted calculated water change, then source, export, and input isolation.
OPEN SHEET → -
NO3-002Observed condition: nitrate at or below detection
Nitrate reads undetectable, or repeatedly bottoms out, confirmed on a second method. 19-step fault tree: zero and persistence confirmation, cyanobacteria attribution gate, carbon-dosing documentation gate, then export and nitrogen-input isolation. Corrections restore input or reduce export one measured step at a time: nothing is dosed from a bottle.
OPEN SHEET → -
PO4-001Observed condition: phosphate rising
Phosphate reads above the applicable upper boundary for your tank type and keeps climbing, confirmed by a second method. 28-step fault tree: reading confirmation, nitrate classification, chemical-removal method boundary, tank-specific critical classification, preflighted calculated water change, then source, export, and input isolation.
OPEN SHEET → -
PO4-002Observed condition: phosphate at or below detection
Phosphate reads undetectable, below the selected method's reporting capability, or repeatedly bottoms out after previously measurable results. 37-step fault tree: method qualification, fresh-sample confirmation, nitrate classification, then five separate removable-cause branches (binding media, lanthanum, carbon dosing, refugium or scrubber export, and input restoration). A confirmed high-nitrate imbalance walks its own route and never enters feeding restoration. Nothing is dosed from a bottle.
OPEN SHEET → -
CA-001Observed condition: calcium not responding to dosing
Dosed calcium fails to rise, or keeps falling, across comparable tests despite an unchanged dosing program. 32-step fault tree: reading and trend confirmation, confound window, magnesium prerequisite, supply and delivery verification, then consumption corroboration.
OPEN SHEET → -
ALK-002Observed condition: alkalinity rising
Alkalinity climbs from test to test while the dosing program sits unchanged. 27-step fault tree: reading and trend confirmation, confound window, kalkwasser and dosing-input checks, delivery verification, then demand corroboration. Every correction reduces an input: nothing is dosed to force the level down.
OPEN SHEET → -
MG-001Observed condition: magnesium decreasing
Magnesium falls across comparable tests spaced days apart despite stable husbandry. 28-step fault tree: reading and trend confirmation, confound window, above-range disposition, supply and delivery verification with a salt-mix check, then calcification corroboration.
OPEN SHEET → -
PH-001Observed condition: pH chronically low
pH reads below the applicable lower boundary at the same time of day on three or more days. 37-step fault tree: meter qualification, high-side exclusion, fresh-reading reproduction, two-sided fresh alkalinity classification, an established kalkwasser program's integrity check, then a three-outcome aeration comparison routing to room-air or aquarium-side causes. Every correction restores something that already existed: nothing is purchased, no new program is started, and no dose is invented.
OPEN SHEET → -
SAL-001Observed condition: salinity drifting
A salinity value, from an ICP report or any home reading, sits outside the acceptable band for the tank type. 28-step fault tree: instrument qualification with a seawater-range standard check, fresh-reading reproduction, severe-deviation screening, direction classification, then top-off and water-source cause isolation. Corrections are a bounded evaporation-substitution raise or a calculated dilution (never dry salt in the tank, never an invented volume), each verified over seven days of same-time readings.
OPEN SHEET →